| Customization: | Available |
|---|---|
| After-sales Service: | 1 Year Within 1000hours |
| Warranty: | 12 Months |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| Diesel Generator Set | GFS-1000KW | ||||||
| MODEL | GFS-1000KW | ||||||
| Prime Power (50Hz) | 1250KVA/1000KW | ||||||
| Standby Power (50Hz) | 1375KVA/1100KW | ||||||
| Standard Features | |||||||
| * Engine (CCEC Cummins KTA50-G3) | |||||||
| * Radiataor 50ºC max,Fas are driven by | |||||||
| Belt,with safety guard | |||||||
| * 24V charge alternator | |||||||
| * Alternator:Single bearing alternator IP23, | |||||||
| insluation class H/H | |||||||
| * Absorber | |||||||
| * Dry type air filter ,fuel filter,oil filter | |||||||
| * Main line circuit breaker | |||||||
| * Standard control panel | |||||||
| * Four 12V batteries ,rack and cable | |||||||
| * Pipple flex exhaust pipe,exhaust siphon | |||||||
| flange,muffler | |||||||
| * User manual | |||||||
| General Rating | |||||||
| RATINGS | Prime Power | Standby Power | |||||
| (PRP) | (ESP) | ||||||
| Voltage (V) | kW | kVA | kW | kVA | |||
| 400/230 | 1000 | 1250 | 1100 | 1375 | |||
| Prime Power (PRP): Prime power is available for an unlimited number of annual hours in variable load | |||||||
| application, in accordance with GB/T2820-97( eqv ISO8528) ; A 10% overload capability is available for a | |||||||
| period of 1 hour within a 12-hour period of operation. | |||||||
| Standby Power Rating (ESP): The standby power rating is applicable for supplying emergency power for | |||||||
| the duration of a utility power interruption. No overload, utility parallel or negotiated outage operation | |||||||
| capability is available at this rating. | |||||||
| Sales Promises | |||||||
| Yihua provides a full line of brand new and high quality products. Each and every unit is strictly factory | |||||||
| tested | |||||||
| Warranty is according to our standard conditions: a, 12 months, counted on the day YIHUA sold to | |||||||
| the first buyer; b. 1000 running hours (accumulated); subject to the earlier one. | |||||||
| Service and parts are available from YIHUA or distributors in your location. | |||||||
| Diesel Generator Set | GFS-1000KW | ||||||
| ENGINE DATA | |||||||
| Manufacturer / Model: | CCEC Cummins KTA50-G3 | ||||||
| Air Intake System: | 4-Cycle; 60° Vee; 16-Cylinder Diesel,Turbocharged and Aftercooled | ||||||
| Fuel System: | PT type fuel pump | ||||||
| Cylinder Arrangement: | 16 in V | ||||||
| Displacement: | 50L | ||||||
| Bore and Stroke: | 159*159(mm) | ||||||
| Compression Ratio | 13.9:1 | ||||||
| Rated RPM: | 1500rpm | ||||||
| Rated Power at Rated RPM: | 1097KW | ||||||
| Continue Power at Rated RPM: | 900KW | ||||||
| Max Power at Rated RPM: | 1227KW | ||||||
| Governor type: | electric | ||||||
| Exhaust System | |||||||
| Exhaust Gas Flow | 7kPa | ||||||
| Max Back Pressure | 5025L/S | ||||||
| Exhaust temperature | 515 ºC | ||||||
| FUEL SYSTEM | |||||||
| Fuel consumption @ 100% (Prime Power) Load | 202 g/kWh | ||||||
| Fuel consumption @ 75% (Prime Power) Load | 206 g/kWh | ||||||
| Fuel consumption @ 50% (Prime Power) Load | 215g/kWh | ||||||
| OIL SYSTEM | |||||||
| Total oil | 176.8L | ||||||
| Oil sump capacity | 121.1-151.4 | ||||||
| COOLING SYSTEM | |||||||
| Coolant capacity(Engine Only) | 160.9 L | ||||||
| Max water temperature | 104ºC(100°F) | ||||||
| Diesel Generator Set | GFS-1000KW | ||||||
| ALTERNATOR SPECIFICATION | |||||||
| Industrial alternators meet the requirements of the relevant parts of the BS5000, VDE 0530, | |||||||
| NEMA MG1-22, IEC34, and AS1359. | |||||||
| Alternator Data | |||||||
| Brannnd/Model | YIHUA TWGII404G | ||||||
| Rated Output | 1000KW | ||||||
| Number of Phase | 3 | ||||||
| Connecting Type | 3 Phase and 4 Wires, Y type connecting | ||||||
| Number of Bearing | 1 | ||||||
| Power Factor | 0.8 | ||||||
| Protection Class | IP23 | ||||||
| Altitude | ≤1000m | ||||||
| Exciter Type | Brushless exciting | ||||||
| Insulation Class/Temperature Rise | H/H | ||||||
| Telephone Influence Factor (TIF) | <50 | ||||||
| THF | <2% | ||||||
| GENERATING SET DATA | |||||||
| Related range of voltage setting | ≥±5% | ||||||
| Steady-state voltage deviation | ≤±1% | ||||||
| Transient voltage deviation (100 % sudden power | ≤+20% | ||||||
| decrease) | |||||||
| Transient voltage deviation (sudden power | ≤-20% | ||||||
| increase) | |||||||
| Voltage recovery time (100 % sudden power decrease) | ≤6S | ||||||
| Voltage recovery time (sudden power increase) | ≤6S | ||||||
| Related range of frequency setting | 0-5% adjustable | ||||||
| Steady-state frequency band | ≤1.5% | ||||||
| Transient frequency deviation (100 % sudden power | ≤-10% | ||||||
| decrease) | |||||||
| Transient frequency deviation (sudden power increase | ≤-7% | ||||||
| Frequency recovery time (100 % sudden power | ≤5S | ||||||
| decrease) | |||||||
| Frequency recovery time (sudden power increase) | ≤5S | ||||||
| Diesel Generator Set | GFS-1000KW | ||||||
| Control | |||||||
| Controller | SMARTGEN | HGM9510 | |||||
| STANDARD FEATURES | |||||||
| Standard auto control system | Exhaust system (including until muffler) |
Documents | |||||
| Oil drain valve | Starting batteries (maintenance-free ) with connective wires |
Special tools | |||||
| MCCB | CHNT NA1-2000X-2000M/3P, Electric stationary | ||||||
| Special Features | |||||||
| 1 | Without fule tank | ||||||
| 2 | FAST 50ºC Radiator ,Cooper | ||||||
| DIMENSIONS & WEIGHT | |||||||
| Container Type | 20 Feet Container | ||||||
| Overall Dimensions: | 6058*2438*2591MM | ||||||
| Weight: | 11200kg | ||||||