Customization: | Available |
---|---|
After-sales Service: | 1 Year Within 1000hours |
Warranty: | 12 Months |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Diesel Generator Set | GFS-1000KW | ||||||
MODEL | GFS-1000KW | ||||||
Prime Power (50Hz) | 1250KVA/1000KW | ||||||
Standby Power (50Hz) | 1375KVA/1100KW | ||||||
Standard Features | |||||||
* Engine (CCEC Cummins KTA50-G3) | |||||||
* Radiataor 50ºC max,Fas are driven by | |||||||
Belt,with safety guard | |||||||
* 24V charge alternator | |||||||
* Alternator:Single bearing alternator IP23, | |||||||
insluation class H/H | |||||||
* Absorber | |||||||
* Dry type air filter ,fuel filter,oil filter | |||||||
* Main line circuit breaker | |||||||
* Standard control panel | |||||||
* Four 12V batteries ,rack and cable | |||||||
* Pipple flex exhaust pipe,exhaust siphon | |||||||
flange,muffler | |||||||
* User manual | |||||||
General Rating | |||||||
RATINGS | Prime Power | Standby Power | |||||
(PRP) | (ESP) | ||||||
Voltage (V) | kW | kVA | kW | kVA | |||
400/230 | 1000 | 1250 | 1100 | 1375 | |||
Prime Power (PRP): Prime power is available for an unlimited number of annual hours in variable load | |||||||
application, in accordance with GB/T2820-97( eqv ISO8528) ; A 10% overload capability is available for a | |||||||
period of 1 hour within a 12-hour period of operation. | |||||||
Standby Power Rating (ESP): The standby power rating is applicable for supplying emergency power for | |||||||
the duration of a utility power interruption. No overload, utility parallel or negotiated outage operation | |||||||
capability is available at this rating. | |||||||
Sales Promises | |||||||
Yihua provides a full line of brand new and high quality products. Each and every unit is strictly factory | |||||||
tested | |||||||
Warranty is according to our standard conditions: a, 12 months, counted on the day YIHUA sold to | |||||||
the first buyer; b. 1000 running hours (accumulated); subject to the earlier one. | |||||||
Service and parts are available from YIHUA or distributors in your location. | |||||||
Diesel Generator Set | GFS-1000KW | ||||||
ENGINE DATA | |||||||
Manufacturer / Model: | CCEC Cummins KTA50-G3 | ||||||
Air Intake System: | 4-Cycle; 60° Vee; 16-Cylinder Diesel,Turbocharged and Aftercooled | ||||||
Fuel System: | PT type fuel pump | ||||||
Cylinder Arrangement: | 16 in V | ||||||
Displacement: | 50L | ||||||
Bore and Stroke: | 159*159(mm) | ||||||
Compression Ratio | 13.9:1 | ||||||
Rated RPM: | 1500rpm | ||||||
Rated Power at Rated RPM: | 1097KW | ||||||
Continue Power at Rated RPM: | 900KW | ||||||
Max Power at Rated RPM: | 1227KW | ||||||
Governor type: | electric | ||||||
Exhaust System | |||||||
Exhaust Gas Flow | 7kPa | ||||||
Max Back Pressure | 5025L/S | ||||||
Exhaust temperature | 515 ºC | ||||||
FUEL SYSTEM | |||||||
Fuel consumption @ 100% (Prime Power) Load | 202 g/kWh | ||||||
Fuel consumption @ 75% (Prime Power) Load | 206 g/kWh | ||||||
Fuel consumption @ 50% (Prime Power) Load | 215g/kWh | ||||||
OIL SYSTEM | |||||||
Total oil | 176.8L | ||||||
Oil sump capacity | 121.1-151.4 | ||||||
COOLING SYSTEM | |||||||
Coolant capacity(Engine Only) | 160.9 L | ||||||
Max water temperature | 104ºC(100°F) | ||||||
Diesel Generator Set | GFS-1000KW | ||||||
ALTERNATOR SPECIFICATION | |||||||
Industrial alternators meet the requirements of the relevant parts of the BS5000, VDE 0530, | |||||||
NEMA MG1-22, IEC34, and AS1359. | |||||||
Alternator Data | |||||||
Brannnd/Model | YIHUA TWGII404G | ||||||
Rated Output | 1000KW | ||||||
Number of Phase | 3 | ||||||
Connecting Type | 3 Phase and 4 Wires, Y type connecting | ||||||
Number of Bearing | 1 | ||||||
Power Factor | 0.8 | ||||||
Protection Class | IP23 | ||||||
Altitude | ≤1000m | ||||||
Exciter Type | Brushless exciting | ||||||
Insulation Class/Temperature Rise | H/H | ||||||
Telephone Influence Factor (TIF) | <50 | ||||||
THF | <2% | ||||||
GENERATING SET DATA | |||||||
Related range of voltage setting | ≥±5% | ||||||
Steady-state voltage deviation | ≤±1% | ||||||
Transient voltage deviation (100 % sudden power | ≤+20% | ||||||
decrease) | |||||||
Transient voltage deviation (sudden power | ≤-20% | ||||||
increase) | |||||||
Voltage recovery time (100 % sudden power decrease) | ≤6S | ||||||
Voltage recovery time (sudden power increase) | ≤6S | ||||||
Related range of frequency setting | 0-5% adjustable | ||||||
Steady-state frequency band | ≤1.5% | ||||||
Transient frequency deviation (100 % sudden power | ≤-10% | ||||||
decrease) | |||||||
Transient frequency deviation (sudden power increase | ≤-7% | ||||||
Frequency recovery time (100 % sudden power | ≤5S | ||||||
decrease) | |||||||
Frequency recovery time (sudden power increase) | ≤5S | ||||||
Diesel Generator Set | GFS-1000KW | ||||||
Control | |||||||
Controller | SMARTGEN | HGM9510 | |||||
STANDARD FEATURES | |||||||
Standard auto control system | Exhaust system (including until muffler) |
Documents | |||||
Oil drain valve | Starting batteries (maintenance-free ) with connective wires |
Special tools | |||||
MCCB | CHNT NA1-2000X-2000M/3P, Electric stationary | ||||||
Special Features | |||||||
1 | Without fule tank | ||||||
2 | FAST 50ºC Radiator ,Cooper | ||||||
DIMENSIONS & WEIGHT | |||||||
Container Type | 20 Feet Container | ||||||
Overall Dimensions: | 6058*2438*2591MM | ||||||
Weight: | 11200kg |